Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (2024)

Ryan Kaufmanrrk26@pitt.eduDepartment of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA  Chenxu LiuPhysical and Computational Sciences, Pacific Northwest National Laboratory, Richland, WA  Katarina CicakNational Institute of Standards and Technology, Boulder, CO  Boris MesitsDepartment of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA  Mingkang XiaDepartment of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA  Chao ZhouDepartment of Applied Physics, Yale University, New Haven, CT  Maria NowickiDepartment of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA  José AumentadoNational Institute of Standards and Technology, Boulder, CO  David PekkerDepartment of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA  Michael HatridgeDepartment of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA

(February 29, 2024)

Abstract

High-fidelity quantum non-demolition qubit measurement is critical to error correction and rapid qubit feedback in large-scale quantum computing. High-fidelity readout requires passing a short and strong pulse through the qubit’s readout resonator, which is then processed by a sufficiently high bandwidth, high saturation power, and quantum-limited amplifier. We have developed a design pipeline that combines time-domain simulation of the un-truncated device Hamiltonian, fabrication constraints, and maximization of saturation power.We have realized an amplifier based on a modified NIST tri-layer Nb fabrication suite which utilizes an array of 25 radio frequency Superconducting QUantum Interference Devices (rf SQUIDS) embedded within a low-Q resonator powered by a high-power voltage pump delivered via a diplexer on the signal port. We show that, despite the intensity of the pump, the device is quantum-efficient and capable of high-fidelity measurement limited by state transitions in the transmon. We present experimental data demonstrating up to 91.291.2-91.2\leavevmode\nobreak\ - 91.2dBm input saturation power with 202020\leavevmode\nobreak\ 20dB gain, up to 282828\leavevmode\nobreak\ 28MHz instantaneous bandwidth, and phase-preserving qubit measurements with 62%percent6262\%62 % quantum efficiency.

Suggested keywords

preprint: AIP/123-QED

I Introduction

Superconducting quantum computers are rapidly scaling to thousands of physical qubits[1]; more, high-fidelity qubit readout is a requirement for both Noisy Intermediate Scale (NISQ)[2] and error-corrected operation of these machines. To avoid further inflation of machine size via the use of ancilla qubits for error correction and other algorithms involving mid-circuit measurements, we require the readout to be Quantum Non-Demolition (QND), which leaves the qubit in the state indicated by the measurement outcome[3].Moreover, dispersive superconducting qubit readout is limited by as yet imperfectly understood non-QND effects for strong readout drives[4, 5, 6, 7], and so one cannot increase the power of the measurement indefinitely to increase measurement fidelity. Further, due to the qubit’s finite T1subscript𝑇1T_{1}italic_T start_POSTSUBSCRIPT 1 end_POSTSUBSCRIPT, one must measure for a time much smaller than T1subscript𝑇1T_{1}italic_T start_POSTSUBSCRIPT 1 end_POSTSUBSCRIPT in order to attain high fidelity. Finally, we need a faithfully linear amplifier to amplify the short, few-photon quantum signal to be unaffected by the added noise of standard 4K commercial amplifiers in the upper stage of the readout chain while adding the minimum amount of noise allowed by quantum mechanics[8, 9].

Generally, we require these high-fidelity, QND measurements for each element of a quantum computer. Frequency multiplexing is a natural solution, allowing many qubit readout resonators to be measured from a single feed line as long as their resonant frequencies are sufficiently spaced. However, this spacing has to be larger than a few linewidths of the resonators to avoid crosstalk, necessitating a large bandwidth[10, 11, 12, 13] of the first amplifier in the chain. The presence of many signals at the same time also requires that the first amplifier also be highly linear, both avoiding compression and excess intermodulation distortion[12, 13].

The Josephson Parametric Amplifier (JPA) is one type of first-stage amplifier that shows promise for its ease of manufacture. The JPA’s megahertz-scale bandwidth typically falls well short of Josephson Travelling Wave Parametric Amplifiers (JTWPAs). However, the difficulty of manufacturing the thousands of junctions required for JTWPAs, their intrinsic loss, and noise-rise near saturation[14], motivates the study of how we can improve the JPA to create a small, easy-to-fabricate, quantum-limited amplifier. The primary shortcoming of simple JPAs with a single junction or loop is that they have very limited saturation power, typically less than 110110-110\leavevmode\nobreak\ - 110dBm[15, 10, 16, 11, 17]. Depending on the choice of qubit parameters, this power may not be enough to amplify more than one or two qubits without distortion from saturation effects within the amplifier[12].Diluting the nonlinearity of single junction/loop devices using a chain of DC SQUIDs, rf SQUIDs, and SNAILs has been explored both theoretically and experimentally, yielding substantially higher saturation power[18, 17, 19, 12, 13].

In this work, we design, fabricate, and characterize an extremely quantum-efficient and high-saturation power amplifier using a simple, single-mode device. The key component of our design process is numerical simulations of the un-truncated device Hamiltonian to fully understand and optimize the device within the constraints of fabrication. The key tuning parameters that we optimized are the device quality factor/impedance and the rf SQUID shunting ratio. The resulting simple design consists of merely two capacitors and an rf SQUID array using 25 junctions. We experimentally realized this device in a modified NIST tri-layer process. We demonstrate input referred saturation powers averaging 94.294.2-94.2\leavevmode\nobreak\ - 94.2dBm (± 1.4plus-or-minus1.4\pm\leavevmode\nobreak\ 1.4\leavevmode\nobreak\ ± 1.4dBm) with 202020\leavevmode\nobreak\ 20dB of power gain with extremes approaching 9191-91\leavevmode\nobreak\ - 91dBm input saturation power and 282828\leavevmode\nobreak\ 28MHz instantaneous bandwidth using only 25 5.5µA5.5timesabsentmicroampere5.5\leavevmode\nobreak\ $\text{\,}\mathrm{\SIUnitSymbolMicro A}${}5.5 start_ARG end_ARG start_ARG times end_ARG start_ARG roman_µ roman_A end_ARG junctions. Additionally, we show that our amplifiers have high quantum efficiency (62% referred to the plane of the qubit), allowing fidelity measurements that are only limited by the qubit’s ability to tolerate photons in the readout resonator, not the amplifier’s saturation power.

II Amplifier Circuit Design and Fabrication

In this section, we present the device simulation and design within the bounds of fabrication. We begin by discussing the shortcomings of previous simulation efforts that truncate the nonlinearity in the device Hamiltonian. Following this, we discuss why we choose rf SQUIDs as our nonlinear elements. We also elaborate on our simulation method, which does not require truncation, and optimize the design parameters within our circuit. Lastly, we translate these optimization results into circuit elements with an added impedance transformation to control device quality factor.

The problem with single-junction or single-loop JPA’s is that even if their bandwidth is broadened to amplify the readout signals of multiple resonators, they struggle to reach the input saturation powers required to simultaneously amplify multiple readout signals at the 202020\leavevmode\nobreak\ 20dB gain required to overwhelm the added noise at the next stage of amplification at 4K[10, 11]. Measurements of this effect are shown directly in[12] in readout on a superconducting processor. This problem of JPA’s lacking power handling can be traced to the current through and phase difference across the Josephson junction at large input signals, which other works have focused on in some other similar amplifier designs[18, 17, 19]. However, these past works depend crucially on expansions of the junction nonlinearity around a particular bias point to find an analytical expression to guide design. While helpful to guide the designer’s intuition at small signal strengths, truncations to the junction Hamiltonian have been shown to obfuscate the high signal power behavior of Josephson junction-based devices[20, 17, 19], sometimes requiring extensions up to seven or eight orders to capture the nonlinear behavior of the junctions near amplifier saturation[20]. Because one of our chief goals is to increase amplifier saturation power, we instead simulate the device at large signal powers by finding a periodic steady-state solution of the device’s classical equation of motion in the time domain. This method is not without its drawbacks. Notably, it is more computationally intensive than methods such as harmonic balance and does not give any analytical understanding of the design. However, crucially, time domain simulations also do not require any simplification or truncation of the sinusoidal nonlinearity of the junction, and so are a far more accurate guide for the design of high-saturation power amplifiers.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (1)

To guide our design, we start with the same strategy as other work with DC SQUIDs[18] and Superconducting Nonlinear Asymmetric Inductive eLements (SNAILs)[21, 17].If the oscillating phase of the signal increases to nearly 2π2𝜋2\pi2 italic_π, higher-order nonlinearities in the sinusoidal potential of the junction begin to become comparable to the third-order nonlinearity required for gain and disrupt amplification. This has been shown previously in similar studies of the same type of behavior in Josephson ring modulators[22, 20] as well as Josephson bifurcation amplifiers[18]. It has also been shown with fourth-order Kerr nonlinearity in SNAIL parametric amplifiers[21, 17, 19, 23]. All of these devices utilize a nonlinear shunt across the junction, formed by Josephson junctions of equal or higher critical currents.For high-inductance versions of these loops, an array of JJs is desirable for producing rather linear arrays with small geometric size. However, for large critical currents/small inductances, such as we use in amplifiers, it becomes quite feasible and desirable to use the geometric inductance of a short superconducting lead as the shunt, which has the additional advantage of eliminating concerns about array modes of the shunt itself [24, 17].

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (2)

This device we refer to as an rf SQUID, though we acknowledge that is method of operation and biasing is rather different than the historical devices given this name [25]. We then carefully consider how best to optimize the circuit to maximize saturation power. To complement the dilution of the current through the junction by the linear inductive shunt, the phase is distributed by even division over an N-element series array similar to past work in Refs [18] and [17]. The full circuit with all external circuit elements is shown in Fig.1(a). The result is similar to designs proposed in[26] but simpler, with only one array instead of two in parallel, albeit without an easy means of delivering flux on-chip over the entire array.

To simulate the device, we begin with the circuit diagram in Fig.A.1(a), with a single nonlinear mode formed from an array of N𝑁Nitalic_N rf SQUIDs of shunt inductance Lssubscript𝐿𝑠L_{s}italic_L start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT in parallel with a Josephson junction with inductance LJsubscript𝐿𝐽L_{J}italic_L start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT resonated by a capacitor C𝐶Citalic_C, and coupled to the external environment of characteristic impedance Z0subscript𝑍0Z_{0}italic_Z start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT around resonance. Assuming that the external magnetic fluxes through the rf SQUID,noted as ϕextsubscriptitalic-ϕext\phi_{\text{ext}}italic_ϕ start_POSTSUBSCRIPT ext end_POSTSUBSCRIPT, are the same, the equation of motion (EOM) can be expressed as

t2ϕ(t)+γtϕ(t)+ωL2ϕ(t)+ωJ2sin[ϕ(t)+ϕextN]=2γtϕin(t),superscriptsubscript𝑡2italic-ϕ𝑡𝛾subscript𝑡italic-ϕ𝑡superscriptsubscript𝜔𝐿2italic-ϕ𝑡superscriptsubscript𝜔𝐽2italic-ϕ𝑡subscriptitalic-ϕext𝑁2𝛾subscript𝑡subscriptitalic-ϕ𝑖𝑛𝑡\begin{split}\partial_{t}^{2}\phi(t)+\gamma\partial_{t}\phi(t)+\omega_{L}^{2}%\phi(t)+\omega_{J}^{2}\sin\left[\frac{\phi(t)+\phi_{\text{ext}}}{N}\right]\\=2\gamma\partial_{t}\phi_{in}(t),\end{split}start_ROW start_CELL ∂ start_POSTSUBSCRIPT italic_t end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT italic_ϕ ( italic_t ) + italic_γ ∂ start_POSTSUBSCRIPT italic_t end_POSTSUBSCRIPT italic_ϕ ( italic_t ) + italic_ω start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT italic_ϕ ( italic_t ) + italic_ω start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT roman_sin [ divide start_ARG italic_ϕ ( italic_t ) + italic_ϕ start_POSTSUBSCRIPT ext end_POSTSUBSCRIPT end_ARG start_ARG italic_N end_ARG ] end_CELL end_ROW start_ROW start_CELL = 2 italic_γ ∂ start_POSTSUBSCRIPT italic_t end_POSTSUBSCRIPT italic_ϕ start_POSTSUBSCRIPT italic_i italic_n end_POSTSUBSCRIPT ( italic_t ) , end_CELL end_ROW(1)

where the phase variable is defined by ϕ(t)=V(t)𝑑titalic-ϕ𝑡𝑉𝑡differential-d𝑡\phi(t)=\int V(t)dtitalic_ϕ ( italic_t ) = ∫ italic_V ( italic_t ) italic_d italic_t (see Fig.A.1a), γ=(CZ0)1𝛾superscript𝐶subscript𝑍01\gamma=(CZ_{0})^{-1}italic_γ = ( italic_C italic_Z start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT ) start_POSTSUPERSCRIPT - 1 end_POSTSUPERSCRIPT is the external decay rate, ωL2=1/(CLsN)superscriptsubscript𝜔𝐿21𝐶subscript𝐿𝑠𝑁\omega_{L}^{2}=1/(CL_{s}\cdot N)italic_ω start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT = 1 / ( italic_C italic_L start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT ⋅ italic_N ) and ωJ2=1/(CLJ)superscriptsubscript𝜔𝐽21𝐶subscript𝐿𝐽\omega_{J}^{2}=1/(CL_{J})italic_ω start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT = 1 / ( italic_C italic_L start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT ) are two frequency constants.

Using this simulation method, we find that controlling the dimensionless ratio of shunt to Josephson inductance LJsubscript𝐿𝐽L_{J}italic_L start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT, β=Ls/LJ𝛽subscript𝐿𝑠subscript𝐿𝐽\beta=L_{s}/L_{J}italic_β = italic_L start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT / italic_L start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT of each rf SQUID in the array and the quality factor Q𝑄Qitalic_Q of the resonator is critical to maximizing the saturation power of the rf SQUID while maintaining its ability to be pumped to produce gain. We find that the device should have approximately the same maximum achievable gain for constant (βQ)1superscript𝛽𝑄1(\beta Q)^{-1}( italic_β italic_Q ) start_POSTSUPERSCRIPT - 1 end_POSTSUPERSCRIPT, shown in Fig.2(c) by different dashed/dash-dot/dotted lines through the design space. This is qualitatively similar to discussions about the pQ𝑝𝑄pQitalic_p italic_Q product in SNAIL and JPC parametric amplfiiers, with Q𝑄Qitalic_Q having the same meaning as here, and p𝑝pitalic_p being a ratio of SNAIL inductance to the total inductance of the mode. Much like in our rf SQUID case, there a higher pQ𝑝𝑄pQitalic_p italic_Q, like (βQ)1superscript𝛽𝑄1(\beta Q)^{-1}( italic_β italic_Q ) start_POSTSUPERSCRIPT - 1 end_POSTSUPERSCRIPT, is "safer" in the sense that it ensures the amplifiers will achieve 20dB of gain[27, 17].

From our numerical calculations, we find that the design parameters Q and β𝛽\betaitalic_β roughly outline a region where the amplifier will fail to achieve 202020\leavevmode\nobreak\ 20dB gain if the rf SQUID is shunted with too small an inductor or the quality factor is too low, as shown by the dashed line determined by a slope (βQ)10.65superscript𝛽𝑄10.65(\beta Q)^{-1}\approx 0.65( italic_β italic_Q ) start_POSTSUPERSCRIPT - 1 end_POSTSUPERSCRIPT ≈ 0.65. For every point in the design space, we choose a flux bias point that maximizes the third-order nonlinearity in the rf-SQUID. However, we also find that variations in the saturation power with respect to flux bias are small in theory (see Fig.A.2(b)). Our principal result is that we also find that the maximum saturation powers of the device occur on the boundary outlined by the same dashed line through the design space in Fig.2 (c) and (d), and can increase the saturation power in a 25-element long array by over 101010\leavevmode\nobreak\ 10dB compared to the lowest values. A higher inductive shunt produces a more nonlinear device with lower saturation power for a given Q, but more tunability in its inductance with respect to flux bias. For mode impedances that are controllably low (such that stray parallel capacitance and series inductances are small compared to the LC resonator that makes up the mode) at 555\leavevmode\nobreak\ 5GHz, this sensitivity corresponds to requiring single micron-scale control over the exact dimensions of the inductive shunt of each rf SQUID in the array. Fig.2(d) shows the design space of the amplifier assuming an N=25𝑁25N=25italic_N = 25 rf-SQUID array in an embedding resonator with ω0/2π6subscript𝜔02𝜋6\omega_{0}/2\pi\approx 6\leavevmode\nobreak\ italic_ω start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT / 2 italic_π ≈ 6GHz.

Based on this understanding, we next scale the circuit by arraying N rf SQUIDs in series. A larger array lowers the nonlinearity by diluting the phase across each rf SQUID, raising the amplifier’s saturation power, but also making it harder to pump. Scaling the array by holding total array inductance constant and decreasing both the individual junction and shunt inductances as the array number increases would increase the saturation flux linearly. This yields quadratic saturation power scaling if one could maintain a constant mode impedance by scaling the junction critical current up and the shunt inductance down indefinitely. However, scaling the junction size up decreases its inductance, and since the designer has to maintain the same shunting ratio, the shunt inductance becomes difficult to control with optical lithography below about 101010\leavevmode\nobreak\ 10pH if the junction size is a few microns. Additionally, the junction side of the rf-SQUID has a stray inductance of a few pH, which can become comparable to the shunt as the scaling is increased. In combination, these effects put a lower bound on the achievable shunt inductance, and therefore an upper bound on the critical current of the junction. With this restriction in mind, we choose to use 25 rf SQUIDs that only require a comfortably low inductance 1215121512-15\leavevmode\nobreak\ 12 - 15pH shunt inductor and 5.5µA5.5timesabsentmicroampere5.5\leavevmode\nobreak\ $\text{\,}\mathrm{\SIUnitSymbolMicro A}${}5.5 start_ARG end_ARG start_ARG times end_ARG start_ARG roman_µ roman_A end_ARG as the basic ingredient for our array.

Our fabricated devices, shown in Fig.2(a) and (b), are fabricated in a modified niobium trilayer process at the National Institute for Standards and Technology’s Boulder Microfabrication Facility (layer specifications given in AppendixC.1), where the high yield and consistency of the junctions allows for excellent device yield in even very long junction arrays[28]. Even so, spatial nonuniformity in the flux biasing in the array (discussed in AppendixC.5 and C.3) presents an issue with verifying device parameters in the experiment. Accordingly, we discuss only the nominal designed values here, with the understanding that these parameters can reasonably vary by 10 percent or so in the real device. We use a shunting ratio of β=0.25𝛽0.25\beta=0.25italic_β = 0.25 for device A, 0.21 for device B, and a junction inductance of 60pH60pH60\leavevmode\nobreak\ \textrm{pH}60 pH.

In total, the rf SQUID array forms about 290290290\leavevmode\nobreak\ 290pH of total effective inductance at zero DC-bias, and between 340340340340 to 390390390\leavevmode\nobreak\ 390pH at the flux bias points which we expect to achieve 202020\leavevmode\nobreak\ 20dB gain. Provided this inductance is paired with a resonant capacitor that produces ω0/2π6subscript𝜔02𝜋6\omega_{0}/2\pi\approx 6\leavevmode\nobreak\ italic_ω start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT / 2 italic_π ≈ 6GHz we arrive at a capacitor value of 1.81.81.81.8 to 222\leavevmode\nobreak\ 2pF. If this mode were directly connected to a 50Ω50Ω50\Omega50 roman_Ω transmission line, we would expect a quality factor Q4𝑄4Q\approx 4italic_Q ≈ 4. However, as mentioned above, we have to alter the quality factor due to the increased inductance of the array compared to the single rf-SQUID. To increase the quality factor well into the region where we expect to achieve 202020\leavevmode\nobreak\ 20dB of gain (see Fig.2(d)), we add a coupling capacitor Cc0.26subscript𝐶𝑐0.26C_{c}\approx 0.26\leavevmode\nobreak\ italic_C start_POSTSUBSCRIPT italic_c end_POSTSUBSCRIPT ≈ 0.26pF to increase the effective environmental impedance on resonance to 100Ωabsent100Ω\approx 100\Omega≈ 100 roman_Ω as seen by the JPA resonator, and increase the quality factor to approximately Q=10𝑄10Q=10italic_Q = 10, with some added variance over bias flux because of the coupling capacitor’s frequency-dependent impedance. The effect of this variation with respect to flux and its consequences for the tunability of the amplifier’s gain is discussed in AppendixC.4.

We measure the packaged JPA chip using a typical qubit readout amplification chain, with a few additions, such as eccosorb filters, a diplexer, and a modified pump line, that are detailed in AppendixC.2.

III Results

Cooled to 151515\leavevmode\nobreak\ 15mK in a dilution refrigerator, and powered with a strong pump at 2ω2𝜔2\omega2 italic_ω the 25-long rf-SQUID array shown in Fig.2(a) and in the larger device in Fig.1(b), is capable of generating a three-wave gain of more than 202020\leavevmode\nobreak\ 20dB over a range of bias points, shown in aggregate in Fig.3(a) with more detail in Fig.C.5(b). To be sure we account for any loss introduced by the amplifier, we take the maximum return loss over all bias fluxes at each frequency as the baseline for gain. After using this pessimistic estimate to tune to 202020\leavevmode\nobreak\ 20dB of gain at each bias point, we measure input signal compression power up to a maximum of 91.591.5-91.5\leavevmode\nobreak\ - 91.5dBm, which is among the highest values reported in the literature for a Josephson junction-based resonant parametric amplifier, in good company with the extreme values of[17, 19, 23], and the average values in other rf-SQUID based devices[12, 13]. Notably, devices of this type achieve similar saturation powers even to JTWPAs that contain almost one hundred times more junctions[29].

Power is calibrated at 5.75.75.7\leavevmode\nobreak\ 5.7GHz by measuring resonator photon number-induced shifts of the qubit’s transition frequency (ω01/2πsubscript𝜔012𝜋\omega_{01}/2\piitalic_ω start_POSTSUBSCRIPT 01 end_POSTSUBSCRIPT / 2 italic_π) combined with separate measurements of the qubit-cavity dispersive shift, detailed in AppendixC.6 along the lines of[30].

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (3)

Average input saturation power values are (94.2±1.4)plus-or-minus94.21.4(-94.2\pm 1.4)\leavevmode\nobreak\ ( - 94.2 ± 1.4 )dBm, with an average instantaneous bandwidth of (20±6)plus-or-minus206(20\pm 6)\leavevmode\nobreak\ ( 20 ± 6 )MHz. As shown in Fig.3(b) with more detail in Fig.C.5, the gain varies somewhat in profile with respect to pump detuning at any given bias point, which we attribute to ripples in the line impedance. Further, because the pessimistic baseline we have chosen for gain is not necessarily flat with respect to frequency and is combined from all bias points, some of the gain profiles are asymmetric with respect to ωp/2subscript𝜔𝑝2\omega_{p}/2italic_ω start_POSTSUBSCRIPT italic_p end_POSTSUBSCRIPT / 2. If we take a less pessimistic baseline, only normalizing to one flux bias point at a time, they appear symmetric as expected. However, some variation in the shape of the loss is expected with the device’s low quality factor because the device responds to changes in the external environment over its linewidth of approximately 300500300500300-500\leavevmode\nobreak\ 300 - 500MHz, with variations over flux bias. This significantly impacts the pumped operation of the device, because the characteristic ripples in the external environment occur on the same 100100100\leavevmode\nobreak\ 100MHz scale. Consequently, the gain profile should take on a modified profile depending on the local slope of the external environment at that particular signal frequency. In addition to the shapes shown, it is possible to see double-peaked gain profiles similar to[11]. We fall short of the expected (GB)\sqrt{(}GB)square-root start_ARG ( end_ARG italic_G italic_B ) gain-bandwidth product for many bias points partly because of this issue of variable port impedance. There is also significant uncertainty in the fit for the device linewidth due to the same impedance ripples, so it is possible the device linewidth may be lower than designed.

The input-referred saturation power of the amplifier depends slightly on bias settings and certain parameters that vary on the 111\leavevmode\nobreak\ 1dB level in the external environment, such as the loss between the resonator cavity and the amplifier chip. Within these variations, the data shows reasonable agreement with the theoretically predicted value from periodic-steady-state analysis of the device equation of motion, shown in Fig.A.2.The high saturation power of the rf-SQUID JPA that we demonstrate is critical for enabling many-qubit readout experiments. However, despite the diplexer’s rejection, the pump power (approximately -25 to -30dBm, based on room temperature loss calibrations) required and the lack of attenuation on the pump line might raise concerns over the thermal photon occupation in the readout resonator and the corresponding limits imposed on T2subscript𝑇2T_{2}italic_T start_POSTSUBSCRIPT 2 end_POSTSUBSCRIPT from thermal photons in the readout resonator dephasing the qubit.

Amplifier State

T1subscript𝑇1T_{1}italic_T start_POSTSUBSCRIPT 1 end_POSTSUBSCRIPT (μs𝜇𝑠\mu sitalic_μ italic_s)

T2,Rsubscript𝑇2𝑅T_{2,R}italic_T start_POSTSUBSCRIPT 2 , italic_R end_POSTSUBSCRIPT (μs𝜇𝑠\mu sitalic_μ italic_s)

T2,Esubscript𝑇2𝐸T_{2,E}italic_T start_POSTSUBSCRIPT 2 , italic_E end_POSTSUBSCRIPT (μs𝜇𝑠\mu sitalic_μ italic_s)

Replaced with short

81

8

20

Off

90

13

26

Detuned -500MHz

93

11

18

On (25dB Gain)

91

6.4

9.1

To address this concern, we measure qubit coherence with varying pump conditions in Table1. We speculate that the presence of the high-power pump line is not meaningfully contributing to decoherence at the 8µs8timesabsentmicrosecond8\leavevmode\nobreak\ $\text{\,}\mathrm{\SIUnitSymbolMicro s}${}8 start_ARG end_ARG start_ARG times end_ARG start_ARG roman_µ roman_s end_ARG level, otherwise we would have expected that the qubit coherence would have improved in the absence of the amplifier and diplexer combination in row 1. It must be noted, however, that this measurement was taken on a different cooldown than the others, and qubits can have significant variation in coherence from cooldown to cooldown. Avoiding dephasing is crucial to the design of high-saturation JPAs, allowing the pump inefficiency to be tolerable in terms of qubit coherence albeit inconvenient for fridge design, requiring specially engineered lines with lower attenuation in order to deliver high power pumps without excess heating. However, we observe the T2Rsubscript𝑇2𝑅T_{2R}italic_T start_POSTSUBSCRIPT 2 italic_R end_POSTSUBSCRIPT time of the qubit dip distinctly when the amplifier is turned on, indicating that the amplifier introduces an extra source of dephasing onto the qubit from the gain alone. This effect is often observed in high-efficiency measurement setups[31, 32], and can be the result of insufficient isolation between the JPA and the readout resonator. To combat this, one can use additional circulators for isolation at the cost of a modest loss in quantum efficiency[13].

In order to calibrate the efficiency of the amplification chain from the plane of the qubit, we can measure the back-action that the amplifier introduces on the qubit. We turn the amplifier on at 252525\leavevmode\nobreak\ 25dB gain, prepare the qubit in the |+Xket𝑋\ket{+X}| start_ARG + italic_X end_ARG ⟩ state, and apply two measurements in sequence according to the pulse diagram in Fig.4(a)[33].

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (4)

The back-action of the weak measurement results in a sinusoidal pattern in the Xcsubscriptdelimited-⟨⟩𝑋𝑐\left<X\right>_{c}⟨ italic_X ⟩ start_POSTSUBSCRIPT italic_c end_POSTSUBSCRIPT and Ycsubscriptdelimited-⟨⟩𝑌𝑐\left<Y\right>_{c}⟨ italic_Y ⟩ start_POSTSUBSCRIPT italic_c end_POSTSUBSCRIPT expectation values in Fig.4(b), with linecuts in Fig.4(c) with respect to the Qmsubscript𝑄𝑚Q_{m}italic_Q start_POSTSUBSCRIPT italic_m end_POSTSUBSCRIPT result of the weak measurement. This sinusoidal pattern has frequency set by the measurement strength Im¯/σ¯subscript𝐼𝑚𝜎\overline{I_{m}}/\sigmaover¯ start_ARG italic_I start_POSTSUBSCRIPT italic_m end_POSTSUBSCRIPT end_ARG / italic_σ, but the amplitude is diminished by an exponential dependent on the measurement strength scaled by the quantum efficiency[33]. Because measurement strength is independently set by the distance between coherent pointer states in the IQ plane, we can fit these oscillations to extract the quantum efficiency. Because the IQ values are dependent on the entire readout chain, the quantum efficiency η𝜂\etaitalic_η that results from the fit represents the efficiency of the entire readout chain, including losses and added noise from the higher-stage amplifiers at 4K4timesabsentkelvin4\leavevmode\nobreak\ $\text{\,}\mathrm{K}${}4 start_ARG end_ARG start_ARG times end_ARG start_ARG roman_K end_ARG and room temperature. Therefore, it acts as a safe lower bound for the efficiency of the rf-SQUID JPA itself.

With this method, we find a measurement efficiency of (0.62±0.014)plus-or-minus0.620.014(0.62\leavevmode\nobreak\ \pm 0.014)( 0.62 ± 0.014 ) on a scale of 0 to 1, without compensating for state preparation and measurement error. This is among the highest reported quantum efficiency values for phase-preserving amplifiers[34, 35, 12, 13], however still not as efficient as phase-sensitive nonreciprocal amplification[32], serving as motivation to pursue integrating amplification closer to the readout resonator itself. The high quantum efficiency of our device also serves as evidence that the high-power nature of the rf-SQUID JPA does not detract from its efficiency.

The projective state readout fidelity of the qubit suffered from a below optimal 2χ/κ=0.3482𝜒𝜅0.3482\chi/\kappa=0.3482 italic_χ / italic_κ = 0.348, where 2χ=0.3482𝜒0.3482\chi=0.348\leavevmode\nobreak\ 2 italic_χ = 0.348MHz is the change in readout resonator frequency between |gket𝑔\ket{g}| start_ARG italic_g end_ARG ⟩ and |eket𝑒\ket{e}| start_ARG italic_e end_ARG ⟩ states of the qubit and κ=1𝜅1\kappa=1\leavevmode\nobreak\ italic_κ = 1MHz is the readout resonator linewidth. So, despite high readout efficiencies, the T1subscript𝑇1T_{1}italic_T start_POSTSUBSCRIPT 1 end_POSTSUBSCRIPT decay of the qubit limits the phase-preserving readout fidelity to 99.3%percent99.399.3\%99.3 % with a 0.8µs0.8timesabsentmicrosecond0.8\leavevmode\nobreak\ $\text{\,}\mathrm{\SIUnitSymbolMicro s}${}0.8 start_ARG end_ARG start_ARG times end_ARG start_ARG roman_µ roman_s end_ARG pulse length, as shown in Fig.4(d). As a result, despite the high saturation power of the amplifier, we were unable to increase the readout power and shorten the pulse time due to readout-induced state transitions in the qubit. For examples of high-power readout histograms, see Fig.C.6.

Higher state transitions in qubit-cavity systems at high cavity occupation is an oft-observed phenomenon[4, 6, 5, 7]. However, it is not entirely without counter. One can design linear filters that take into account quantum noise and T1subscript𝑇1T_{1}italic_T start_POSTSUBSCRIPT 1 end_POSTSUBSCRIPT decay[36, 37]. Even with such filters the behavior of transmon qubits at very high readout resonator occupations is generally detrimental to readout performance, and remains a barrier to fast, high-fidelity, QND measurement. Future work to improve the state of the art, including the study of transmon dynamics at high power, will hopefully be enabled by a robust measurement chain that can easily tolerate the measurement powers that drive transmons into behavior resembling chaos[7].

IV Conclusion

To conclude, we have experimentally demonstrated the effectiveness of periodic steady-state simulations for capturing JPA dynamics. Using these tools we have successfully designed, built, and fabricated a high saturation power JPA built on rf-SQUID arrays with enough power handling capability for hundreds of channels of simultaneous measurements, albeit without the bandwidth to demonstrate this capability. Additionally, we have shown that despite the device’s need for a high-power pump, it does not reduce qubit coherence beyond what is expected for a single stage of isolation, which can be further circumvented by pulsing the amplifier. In addition, the device maintains quantum efficiency on par with some of the best examples of phase-preserving amplification in the literature. We show high fidelity measurement limited primarily by readout-activated state transitions in the qubit at high powers, rather than any property of amplifier itself. The non-QND nature of strong measurement tones in circuit QED remains an open problem for the field which motivates the pursuit of optimal filtering[37] and a greater understanding of the limitations of the limits of dispersive readout in circuit QED[5, 7, 38].

Future work includes engineering a robust matching network to broaden the gain response of this amplifier with techniques similar to[39, 13]. However, we note that while these techniques outline an elegant solution that traces roots back to filter synthesis, the technique must also be unified with the saturation power calculations demonstrated in this work which account for the full nonlinearity of the Josephson junction to further assist the designer in anticipating saturation effects. More, we should implement a dedicated pump coupling port that can avoid the inefficiency of the coupling capacitor as a means of delivering the AC driving phase to the junction at the pump frequency. This could effectively integrate the external diplexer on-chip, which can be feasibly implemented with the existing fabrication process, which will greatly simplify the external circuitry required to operate the amplifier and conceivably reduce the loss between the amplifier and qubit to further increase the efficiency of measurements. Additional research is also being done on how to increase the amplifier’s power-added efficiency once the pump reaches the resonator node[40]. In all, we demonstrate a simple and highly linear amplifier that can serve as a stepping stone for these innovations and as a workhorse in near-term quantum information experiments, including the study of the QNDnesss of strong qubit readout.

Acknowledgements

We are grateful to the Peterson Institute for Nanoscience and Engineering for support in the fabrication of the qubit used for measurement. We thank Chao Zhou and Pinlei Lu for their work and helpful guidance on the control and measurement software.This manuscript isbased upon work supported in part by the U.S. ArmyResearch Office under Grant No. W911NF-15-1-0397 and the National Institute of Standards & Technology (NIST) Quantum Information Program. Boris Mesits was supported by the NSF GRFP. This material is based upon work supported in part by the U.S. Department of Energy, Office of Science, National Quantum Information Science Research Centers, Co-design Center for Quantum Advantage (C2QA) under contract number DE-SC0012704, (Basic Energy Sciences, PNNL FWP 76274). The Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy under Contract DE-AC05-76RL01830.This is a contribution of the National Institute of Standards and Technology, not subject to U.S. copyright. Any identification of commercial equipment, instruments, or materials in this paper is to foster understanding; it does not imply neither the recommendation or endorsem*nt by the National Institute of Standards and Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.

References

  • IBM [2024]IBM quantum roadmap to build quantum-centric supercomputers | IBM research blog (2024),https://research.ibm.com/blog/ibm-quantum-roadmap-2025.
  • Preskill [2018]J.Preskill,Quantum Computing in the NISQ era and beyond,Quantum2,79 (2018).
  • NielsenandChuang [2010]M.A.NielsenandI.L.Chuang,Quantum Computation and Quantum Information: 10th Anniversary Edition(Cambridge University Press,2010).
  • Sanketal. [2016]D.Sank, Z.Chen, M.Khezri, J.Kelly, R.Barends, B.Campbell, Y.Chen, B.Chiaro, A.Dunsworth, A.Fowler, E.Jeffrey, E.Lucero, A.Megrant, J.Mutus, M.Neeley, C.Neill, P.J.O’Malley, C.Quintana, P.Roushan, A.Vainsencher, T.White, J.Wenner, A.N.Korotkov,andJ.M.Martinis,Measurement-induced state transitions in a superconducting qubit: Beyond the rotating wave approximation,Physical Review Letters117,190503 (2016).
  • Shillitoetal. [2022]R.Shillito, A.Petrescu, J.Cohen, J.Beall, M.Hauru, M.Ganahl, A.G.Lewis, G.Vidal,andA.Blais,Dynamics of transmon ionization,Physical Review Applied18,034031 (2022).
  • Khezrietal. [2023]M.Khezri, A.Opremcak, Z.Chen, K.C.Miao, M.McEwen, A.Bengtsson, T.White, O.Naaman, D.Sank, A.N.Korotkov, Y.Chen,andV.Smelyanskiy,Measurement-induced state transitions in a superconducting qubit: Within the rotating-wave approximation,Physical Review Applied20,054008 (2023).
  • Cohenetal. [2023]J.Cohen, A.Petrescu, R.Shillito,andA.Blais,Reminiscence of classical chaos in driven transmons,PRX Quantum4,020312 (2023).
  • Cavesetal. [2012]C.M.Caves, J.Combes, Z.Jiang,andS.Pandey,Quantum limits on phase-preserving linear amplifiers,Physical Review A - Atomic, Molecular, and Optical Physics86,063802 (2012).
  • Clerketal. [2010]A.A.Clerk, M.H.Devoret, S.M.Girvin, F.Marquardt,andR.J.Schoelkopf,Introduction to quantum noise, measurement, and amplification,Reviews of Modern Physics82,1155 (2010).
  • Mutusetal. [2014]J.Y.Mutus, T.C.White, R.Barends, Y.Chen, Z.Chen, B.Chiaro, A.Dunsworth, E.Jeffrey, J.Kelly, A.Megrant, C.Neill, P.J.O’Malley, P.Roushan, D.Sank, A.Vainsencher, J.Wenner, K.M.Sundqvist, A.N.Cleland,andJ.M.Martinis,Strong environmental coupling in a Josephson parametric amplifier,Applied Physics Letters104,263513 (2014).
  • Royetal. [2015]T.Roy, S.Kundu, M.Chand, A.M.Vadiraj, A.Ranadive, N.Nehra, M.P.Patankar, J.Aumentado, A.A.Clerk,andR.Vijay,Broadband parametric amplification with impedance engineering: Beyond the gain-bandwidth product,Applied Physics Letters107,262601 (2015).
  • Whiteetal. [2023]T.White, A.Opremcak, G.Sterling, A.Korotkov, D.Sank, R.Acharya, M.Ansmann, F.Arute, K.Arya, J.C.Bardin, A.Bengtsson, A.Bourassa, J.Bovaird, L.Brill, B.B.Buckley, D.A.Buell, T.Burger, B.Burkett, N.Bushnell, Z.Chen, B.Chiaro, J.Cogan, R.Collins, A.L.Crook, B.Curtin, S.Demura, A.Dunsworth, C.Erickson, R.Fatemi, L.F.Burgos, E.Forati, B.Foxen, W.Giang, M.Giustina, A.G.Dau, M.C.Hamilton, S.D.Harrington, J.Hilton, M.Hoffmann, S.Hong, T.Huang, A.Huff, J.Iveland, E.Jeffrey, M.Kieferová, S.Kim, P.V.Klimov, F.Kostritsa, J.M.Kreikebaum, D.Landhuis, P.Laptev, L.Laws, K.Lee, B.J.Lester, A.Lill, W.Liu, A.Locharla, E.Lucero, T.McCourt, M.McEwen, X.Mi, K.C.Miao, S.Montazeri, A.Morvan, M.Neeley, C.Neill, A.Nersisyan, J.H.Ng, A.Nguyen, M.Nguyen, R.Potter, C.Quintana, P.Roushan, K.Sankaragomathi, K.J.Satzinger, C.Schuster, M.J.Shearn, A.Shorter, V.Shvarts, J.Skruzny, W.C.Smith, M.Szalay, A.Torres, B.W.Woo, Z.J.Yao, P.Yeh, J.Yoo, G.Young, N.Zhu, N.Zobrist, Y.Chen, A.Megrant, J.Kelly,andO.Naaman,Readout of a quantum processor with high dynamic range Josephson parametric amplifiers,Applied Physics Letters122,14001 (2023).
  • Kaufmanetal. [2023]R.Kaufman, T.White, M.I.Dykman, A.Iorio, G.Stirling, S.Hong, A.Opremcak, A.Bengtsson, L.Faoro, J.C.Bardin, T.Burger, R.Gasca,andO.Naaman,Josephson parametric amplifier with chebyshev gain profile and high saturation,Physical Review Applied20,054058 (2023).
  • Remmetal. [2023]A.Remm, S.Krinner, N.Lacroix, C.Hellings, F.Swiadek, G.J.Norris, C.Eichler,andA.Wallraff,Intermodulation distortion in a Josephson traveling-wave parametric amplifier,Physical Review Applied20,034027 (2023).
  • Yamamotoetal. [2008]T.Yamamoto, K.Inomata, M.Watanabe, K.Matsuba, T.Miyazaki, W.D.Oliver, Y.Nakamura,andJ.S.Tsai,Flux-driven Josephson parametric amplifier,Applied Physics Letters93,42510 (2008).
  • Zhouetal. [2014]X.Zhou, V.Schmitt, P.Bertet, D.Vion, W.Wustmann, V.Shumeiko,andD.Esteve,High-gain weakly nonlinear flux-modulated Josephson parametric amplifier using a squid array,Physical Review B - Condensed Matter and Materials Physics89,214517 (2014).
  • Frattinietal. [2018]N.E.Frattini, V.V.Sivak, A.Lingenfelter, S.Shankar,andM.H.Devoret,Optimizing the nonlinearity and dissipation of a SNAIL parametric amplifier for dynamic range,Physical Review Applied10,054020 (2018).
  • KochetovandFedorov [2015]B.A.KochetovandA.Fedorov,Higher-order nonlinear effects in a Josephson parametric amplifier,Physical Review B - Condensed Matter and Materials Physics92,224304 (2015).
  • Sivaketal. [2019]V.V.Sivak, N.E.Frattini, V.R.Joshi, A.Lingenfelter, S.Shankar,andM.H.Devoret,Kerr-free three-wave mixing in superconducting quantum circuits,Physical Review Applied11,054060 (2019).
  • Liuetal. [2020]C.Liu, T.C.Chien, M.Hatridge,andD.Pekker,Optimizing Josephson-ring-modulator-based Josephson parametric amplifiers via full Hamiltonian control,Physical Review A101,042323 (2020).
  • Frattinietal. [2017]N.E.Frattini, U.Vool, S.Shankar, A.Narla, K.M.Sliwa,andM.H.Devoret,3-wave mixing Josephson dipole element,Applied Physics Letters110,222603 (2017).
  • Liuetal. [2017]G.Liu, T.C.Chien, X.Cao, O.Lanes, E.Alpern, D.Pekker,andM.Hatridge,Josephson parametric converter saturation and higher order effects,Applied Physics Letters111,20 (2017).
  • Sivaketal. [2020]V.V.Sivak, S.Shankar, G.Liu, J.Aumentado,andM.H.Devoret,Josephson array-mode parametric amplifier,Physical Review Applied10,24014 (2020).
  • Masluketal. [2012]N.A.Masluk, I.M.Pop, A.Kamal, Z.K.Minev,andM.H.Devoret,Microwave characterization of josephson junction arrays: Implementing a low loss superinductance,Physical Review Letters109,137002 (2012).
  • ClarkeandBraginski [2005]J.ClarkeandA.I.Braginski,The SQUID Handbook,Vol.1(Wiley Blackwell,2005)pp.1–395.
  • Naamanetal. [2019]O.Naaman, D.G.Ferguson, A.Marakov, M.Khalil, W.F.Koehl,andR.J.Epstein,High saturation power Josephson parametric amplifier with ghz bandwidth,IEEE MTT-S International Microwave Symposium Digest2019-June,259 (2019).
  • Bergealetal. [2010]N.Bergeal, R.Vijay, V.E.Manucharyan, I.Siddiqi, R.J.Schoelkopf, S.M.Girvin,andM.H.Devoret,Analog information processing at the quantum limit with a josephson ring modulator,Nature Physics 2010 6:46,296 (2010).
  • Niemeyeretal. [1985]J.Niemeyer, L.Grimm, W.Meier, J.H.Hinken,andE.Vollmer,Stable josephson reference voltages between 0.1 and 1.3 v for high-precision voltage standards,Applied Physics Letters47,1222 (1985).
  • Macklinetal. [2015]C.Macklin, K.O’Brien, D.Hover, M.E.Schwartz, V.Bolkhovsky, X.Zhang, W.D.Oliver,andI.Siddiqi,A nearâ€"quantum-limited Josephson traveling-wave parametric amplifier,Science350,307 (2015).
  • Schuster [2007]D.I.Schuster,Circuit Quantum Electrodynamics,Ph.D. thesis,Applied Physics (2007).
  • Lecocqetal. [2017]F.Lecocq, L.Ranzani, G.A.Peterson, K.Cicak, R.W.Simmonds, J.D.Teufel,andJ.Aumentado,Nonreciprocal microwave signal processing with a field-programmable Josephson amplifier,Physical Review Applied7,024028 (2017).
  • Lecocqetal. [2021]F.Lecocq, L.Ranzani, G.A.Peterson, K.Cicak, X.Y.Jin, R.W.Simmonds, J.D.Teufel,andJ.Aumentado,Efficient qubit measurement with a nonreciprocal microwave amplifier,Physical Review Letters126,020502 (2021).
  • Hatridgeetal. [2013]M.Hatridge, S.Shankar, M.Mirrahimi, F.Schackert, K.Geerlings, T.Brecht, K.M.Sliwa, B.Abdo, L.Frunzio, S.M.Girvin, R.J.Schoelkopf,andM.H.Devoret,Quantum back-action of an individual variable-strength measurement,Science339,178 (2013).
  • Walteretal. [2017]T.Walter, P.Kurpiers, S.Gasparinetti, P.Magnard, A.Potočnik, Y.Salathé, M.Pechal, M.Mondal, M.Oppliger, C.Eichler,andA.Wallraff,Rapid high-fidelity single-shot dispersive readout of superconducting qubits,Physical Review Applied7,054020 (2017).
  • Touzardetal. [2019]S.Touzard, A.Kou, N.E.Frattini, V.V.Sivak, S.Puri, A.Grimm, L.Frunzio, S.Shankar,andM.H.Devoret,Gated conditional displacement readout of superconducting qubits,Physical Review Letters122,10.1103/PhysRevLett.122.080502 (2019).
  • Gambettaetal. [2007]J.Gambetta, W.A.Braff, A.Wallraff, S.M.Girvin,andR.J.Schoelkopf,Protocols for optimal readout of qubits using a continuous quantum nondemolition measurement,Physical Review A - Atomic, Molecular, and Optical Physics76,012325 (2007).
  • Khanetal. [2023]S.A.Khan, R.Kaufman, B.Mesits, M.Hatridge,andH.E.Türeci,Practical trainable temporal post-processor for multi-state quantum measurement (2023),https://arxiv.org/abs/2310.18519v1).
  • Dumasetal. [2024]M.F.Dumas, B.Groleau-Paré, A.McDonald, M.H.Muñoz-Arias, C.Lledó, B.D’Anjou,andA.Blais,Unified picture of measurement-induced ionization in the transmon, (2024).
  • NaamanandAumentado [2022]O.NaamanandJ.Aumentado,Synthesis of parametrically coupled networks,PRX Quantum3,020201 (2022).
  • Houglandetal. [2024]N.M.Hougland, Z.Li, R.Kaufman, B.Mesits, R.Mong, M.Hatridge,andD.Pekker,In PreparationarXiv:2402.12586 (2024).

Appendix A Periodic steady-state simulation

We analyze the dynamics of the rf-SQUID amplifier using periodic steady-state simulation similar to the methods used to analyze Josephson Ring Modulators in [20], starting from equation given in the main text by Eq.1. Note that the phase variable ϕ(t)italic-ϕ𝑡\phi(t)italic_ϕ ( italic_t ) has DC components, noted as ϕDCsubscriptitalic-ϕDC\phi_{\text{DC}}italic_ϕ start_POSTSUBSCRIPT DC end_POSTSUBSCRIPT, and hence ϕ(t)=φ(t)+ϕDCitalic-ϕ𝑡𝜑𝑡subscriptitalic-ϕDC\phi(t)=\varphi(t)+\phi_{\text{DC}}italic_ϕ ( italic_t ) = italic_φ ( italic_t ) + italic_ϕ start_POSTSUBSCRIPT DC end_POSTSUBSCRIPT. The DC component can be determined by the current relation in each rf-SQUID,

ϕDCLsN+1LJsin(ΔϕN)=0,subscriptitalic-ϕDCsubscript𝐿𝑠𝑁1subscript𝐿𝐽Δitalic-ϕ𝑁0\frac{\phi_{\text{DC}}}{L_{s}\cdot N}+\frac{1}{L_{J}}\sin\left(\frac{\Delta%\phi}{N}\right)=0,divide start_ARG italic_ϕ start_POSTSUBSCRIPT DC end_POSTSUBSCRIPT end_ARG start_ARG italic_L start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT ⋅ italic_N end_ARG + divide start_ARG 1 end_ARG start_ARG italic_L start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT end_ARG roman_sin ( divide start_ARG roman_Δ italic_ϕ end_ARG start_ARG italic_N end_ARG ) = 0 ,(2)

where we define Δϕ=ϕDC+ϕextΔitalic-ϕsubscriptitalic-ϕDCsubscriptitalic-ϕext\Delta\phi=\phi_{\text{DC}}+\phi_{\text{ext}}roman_Δ italic_ϕ = italic_ϕ start_POSTSUBSCRIPT DC end_POSTSUBSCRIPT + italic_ϕ start_POSTSUBSCRIPT ext end_POSTSUBSCRIPT.

By separating the DC and AC components, we rewrite the EOM in Eq.(1) as

t2φ(t)+γt2φ(t)+ω02φ(t)+ωJ2[sin(φ(t)+ΔϕN)sin(ΔϕN)φNcos(ΔϕN)ϕ(t)]=2γtϕin(t),superscriptsubscript𝑡2𝜑𝑡𝛾superscriptsubscript𝑡2𝜑𝑡superscriptsubscript𝜔02𝜑𝑡superscriptsubscript𝜔𝐽2delimited-[]𝜑𝑡Δitalic-ϕ𝑁Δitalic-ϕ𝑁𝜑𝑁Δitalic-ϕ𝑁italic-ϕ𝑡2𝛾subscript𝑡subscriptitalic-ϕ𝑖𝑛𝑡\partial_{t}^{2}\varphi(t)+\gamma\partial_{t}^{2}\varphi(t)+\omega_{0}^{2}%\varphi(t)+\omega_{J}^{2}\left[\sin\left(\frac{\varphi(t)+\Delta\phi}{N}\right%)-\sin\left(\frac{\Delta\phi}{N}\right)-\frac{\varphi}{N}\cos\left(\frac{%\Delta\phi}{N}\right)\phi(t)\right]=2\gamma\partial_{t}\phi_{in}(t),∂ start_POSTSUBSCRIPT italic_t end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT italic_φ ( italic_t ) + italic_γ ∂ start_POSTSUBSCRIPT italic_t end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT italic_φ ( italic_t ) + italic_ω start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT italic_φ ( italic_t ) + italic_ω start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT [ roman_sin ( divide start_ARG italic_φ ( italic_t ) + roman_Δ italic_ϕ end_ARG start_ARG italic_N end_ARG ) - roman_sin ( divide start_ARG roman_Δ italic_ϕ end_ARG start_ARG italic_N end_ARG ) - divide start_ARG italic_φ end_ARG start_ARG italic_N end_ARG roman_cos ( divide start_ARG roman_Δ italic_ϕ end_ARG start_ARG italic_N end_ARG ) italic_ϕ ( italic_t ) ] = 2 italic_γ ∂ start_POSTSUBSCRIPT italic_t end_POSTSUBSCRIPT italic_ϕ start_POSTSUBSCRIPT italic_i italic_n end_POSTSUBSCRIPT ( italic_t ) ,(3)

where the mode resonant frequency is given by

ω02=ωL2+ωJ2Ncos(ΔϕN)=1NC[1Ls+1LJcos(ΔϕN)].superscriptsubscript𝜔02superscriptsubscript𝜔𝐿2superscriptsubscript𝜔𝐽2𝑁Δitalic-ϕ𝑁1𝑁𝐶delimited-[]1subscript𝐿𝑠1subscript𝐿𝐽Δitalic-ϕ𝑁\omega_{0}^{2}=\omega_{L}^{2}+\frac{\omega_{J}^{2}}{N}\cos\left(\frac{\Delta%\phi}{N}\right)=\frac{1}{NC}\left[\frac{1}{L_{s}}+\frac{1}{L_{J}}\cos\left(%\frac{\Delta\phi}{N}\right)\right].italic_ω start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT = italic_ω start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT + divide start_ARG italic_ω start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT end_ARG start_ARG italic_N end_ARG roman_cos ( divide start_ARG roman_Δ italic_ϕ end_ARG start_ARG italic_N end_ARG ) = divide start_ARG 1 end_ARG start_ARG italic_N italic_C end_ARG [ divide start_ARG 1 end_ARG start_ARG italic_L start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT end_ARG + divide start_ARG 1 end_ARG start_ARG italic_L start_POSTSUBSCRIPT italic_J end_POSTSUBSCRIPT end_ARG roman_cos ( divide start_ARG roman_Δ italic_ϕ end_ARG start_ARG italic_N end_ARG ) ] .(4)
Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (5)

To calculate the pump power that produces 202020\leavevmode\nobreak\ 20dB gain, we apply a procedure similar to the tuneup of the real amplifier. At a particular flux value, we can turn up the pump power and analyze the gain of a weak signal. Repeating this process over a half-quanta of flux values produces a plot shown in Fig.A.2(a), showing a contour of gain points that are all viable bias points. We have divided this contour in two pieces, representing the lower pump power 202020\leavevmode\nobreak\ 20dB gain points in green, and the higher pump power points in red. Despite also looking like 202020\leavevmode\nobreak\ 20dB gain points, points along the red contour are not guaranteed stability and so we neglect them in the analysis, continuing with only the bias points along the green curve. To investigate the variation over the flux bias of the simulated amplifier, we move along the green contour, testing both the saturation power P1dBsubscript𝑃1dBP_{-1\text{dB}}italic_P start_POSTSUBSCRIPT - 1 dB end_POSTSUBSCRIPT and the core power added efficiency

ηPAE=Pout,1dB(ωs)Pin(ωs)Ppump(ωp)subscript𝜂𝑃𝐴𝐸subscript𝑃out1dBsubscript𝜔𝑠subscript𝑃insubscript𝜔𝑠subscript𝑃pumpsubscript𝜔𝑝\eta_{PAE}=\frac{P_{\text{out},1\text{dB}}(\omega_{s})-P_{\text{in}}(\omega_{s%})}{P_{\text{pump}}(\omega_{p})}italic_η start_POSTSUBSCRIPT italic_P italic_A italic_E end_POSTSUBSCRIPT = divide start_ARG italic_P start_POSTSUBSCRIPT out , 1 dB end_POSTSUBSCRIPT ( italic_ω start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT ) - italic_P start_POSTSUBSCRIPT in end_POSTSUBSCRIPT ( italic_ω start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT ) end_ARG start_ARG italic_P start_POSTSUBSCRIPT pump end_POSTSUBSCRIPT ( italic_ω start_POSTSUBSCRIPT italic_p end_POSTSUBSCRIPT ) end_ARG

(which reduces to approximately Pout,1dB/Ppumpsubscript𝑃out1dBsubscript𝑃pumpP_{\text{out},-1\text{dB}}/P_{\text{pump}}italic_P start_POSTSUBSCRIPT out , - 1 dB end_POSTSUBSCRIPT / italic_P start_POSTSUBSCRIPT pump end_POSTSUBSCRIPT at 202020\leavevmode\nobreak\ 20dB gain and near amplifier saturation) at each bias point of the amplifier, with the results shown in Fig. A.2(b)-(c). We find only weak variation in saturation power, but more pronounced variation in the pump efficiency at saturation.

The marginal variation is seen along the bias flux for saturation power, reinforcing notions put forward in [19] and [20] that the static Kerr of the amplifier mode does not act as the primary control of the saturation power, however the significant variation in pump power without a change in saturation power also complicates attributing saturation solely to pump depletion. It may be possible, for example, that the effects of Kerr and pump depletion are opposed to one another in how they affect saturation, with the low (static) Kerr bias points toward ϕext0.25ϕ0subscriptitalic-ϕext0.25subscriptitalic-ϕ0\phi_{\text{ext}}\approx 0.25\phi_{0}italic_ϕ start_POSTSUBSCRIPT ext end_POSTSUBSCRIPT ≈ 0.25 italic_ϕ start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT having more saturation power relative to the pump, but less pump power to draw from at 202020\leavevmode\nobreak\ 20dB gain. Continued study of this equation of motion is necessary to explain these effects in greater detail[40].

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (6)
Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (7)

Lastly, we sweep through a significant subset of all possible families of amplifiers of this circuit type to investigate how both the pump power added efficiency and the pump power required to achieve 202020\leavevmode\nobreak\ 20dB gain vary. In Fig.A.3(a) we see that within a given gain family of amplifiers (a vertical line cut through either (a) it (b)), the required pump power increases with respect to the quality factor, and in general that the higher saturation power families of amplifiers determined by the x-axis coordinate require disproportionately higher pump powers at higher quality factors.

We can see this disproportionality directly in Fig.A.3(b), which shows that the pump efficiency drops significantly with higher quality factor and decreases yet more as one designs for larger and larger (higher and higher saturation power) (βQ)1superscript𝛽𝑄1(\beta Q)^{-1}( italic_β italic_Q ) start_POSTSUPERSCRIPT - 1 end_POSTSUPERSCRIPT. We note that despite the simulated pump efficiency of approximately 2020-20\leavevmode\nobreak\ - 20dB for the parameters of our devices, the amplifier in this work performs worse in total efficiency, only achieving approximately 4040-40\leavevmode\nobreak\ - 40dB pump efficiency because of the pump reflecting off of the coupling capacitor, discussed in AppendixB.

Appendix B Pump efficiency

The advantage of utilizing a 3-wave JPA over a 4-wave JPA is the ability to use a single pump at twice the signal frequency, generally reducing the pump leakage into the signal band of the readout chain and making it easier to implement filters to further reduce pump leakage. However, this advantage comes at a cost, which is that the behavior of the circuit near the pumping frequencies has to be carefully considered independently of the behavior at the signal frequencies. For example, it is possible that far away from the signal band it is challenging to get the pump tone to interact with the parametric core of the system that you are driving, significantly raising the pump power requirements of the amplifier and possibly heating the dilution refrigerator it resides in. Therefore, it is important to consider how effectively a certain input pump power drives parametric processes.

Generally, the efficiency metric that most directly impacts the surroundings of the JPA is power added efficiency (PAE) which expresses efficiency as a ratio of the output power at the signal frequency minus the input power at the signal frequency in ratio to the pump power at the pump frequency,

PAE=Pout(ωs)Pin(ωs)Ppump(ωp).𝑃𝐴𝐸subscript𝑃𝑜𝑢𝑡subscript𝜔𝑠subscript𝑃𝑖𝑛subscript𝜔𝑠subscript𝑃𝑝𝑢𝑚𝑝subscript𝜔𝑝PAE=\frac{P_{out}(\omega_{s})-P_{in}(\omega_{s})}{P_{pump}(\omega_{p})}.italic_P italic_A italic_E = divide start_ARG italic_P start_POSTSUBSCRIPT italic_o italic_u italic_t end_POSTSUBSCRIPT ( italic_ω start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT ) - italic_P start_POSTSUBSCRIPT italic_i italic_n end_POSTSUBSCRIPT ( italic_ω start_POSTSUBSCRIPT italic_s end_POSTSUBSCRIPT ) end_ARG start_ARG italic_P start_POSTSUBSCRIPT italic_p italic_u italic_m italic_p end_POSTSUBSCRIPT ( italic_ω start_POSTSUBSCRIPT italic_p end_POSTSUBSCRIPT ) end_ARG .

We have already simulated ηPAEsubscript𝜂𝑃𝐴𝐸\eta_{PAE}italic_η start_POSTSUBSCRIPT italic_P italic_A italic_E end_POSTSUBSCRIPT for the core of the amplifier (without the capacitive coupler) in AppendixA, shown in Fig.A.3(b), and so we will define another quantity that captures the difference between the input coupling at the signal frequency, captured effectively by the decay rate γ𝛾\gammaitalic_γ, and the pump frequency. This difference is not modeled in the periodic steady-state simulation, which uses the same decay rate for both signal and pump. To model the real circuit, which uses a coupling capacitor to alter the real part of the impedance on resonance, we will modify the "core efficiency" shown in Fig.A.3(b) by another factor which we will calculate as a function of any coupling impedance.

As detailed in AppendixA, the driving term we are concerned with is the circulating phase at the core node of the amplifier, which is the phase across the rf-SQUID array element. To model the effect of any arbitrary coupling series impedance, we consider the circuit below in Fig.B.1.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (8)

For the particular case of a series coupling impedance, the result is easily attainable by voltage division, allowing us to find the power dissipating in the real impedance outside the amplifier, given by Pa=|Va,p|2/(2Z0)subscript𝑃𝑎superscriptsubscript𝑉𝑎𝑝22subscript𝑍0P_{a}=|V_{a,p}|^{2}/(2Z_{0})italic_P start_POSTSUBSCRIPT italic_a end_POSTSUBSCRIPT = | italic_V start_POSTSUBSCRIPT italic_a , italic_p end_POSTSUBSCRIPT | start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT / ( 2 italic_Z start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT ), as a function of the impedances and the required circulating phase

Pa=12Z0Re[|ϕpΦ02πiω(1+ZZL)|2],subscript𝑃𝑎12subscript𝑍0𝑅𝑒delimited-[]superscriptsubscriptitalic-ϕ𝑝subscriptΦ02𝜋𝑖𝜔1𝑍subscript𝑍𝐿2P_{a}=\frac{1}{2Z_{0}}Re[|\frac{\phi_{p}\Phi_{0}}{2\pi}i\omega(1+\frac{Z}{Z_{L%}})|^{2}],italic_P start_POSTSUBSCRIPT italic_a end_POSTSUBSCRIPT = divide start_ARG 1 end_ARG start_ARG 2 italic_Z start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT end_ARG italic_R italic_e [ | divide start_ARG italic_ϕ start_POSTSUBSCRIPT italic_p end_POSTSUBSCRIPT roman_Φ start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT end_ARG start_ARG 2 italic_π end_ARG italic_i italic_ω ( 1 + divide start_ARG italic_Z end_ARG start_ARG italic_Z start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT end_ARG ) | start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT ] ,

where ϕpsubscriptitalic-ϕ𝑝\phi_{p}italic_ϕ start_POSTSUBSCRIPT italic_p end_POSTSUBSCRIPT and Vasubscript𝑉𝑎V_{a}italic_V start_POSTSUBSCRIPT italic_a end_POSTSUBSCRIPT are complex amplitudes for ϕ(t)=ϕpeiωtitalic-ϕ𝑡subscriptitalic-ϕ𝑝superscript𝑒𝑖𝜔𝑡\phi(t)=\phi_{p}e^{-i\omega t}italic_ϕ ( italic_t ) = italic_ϕ start_POSTSUBSCRIPT italic_p end_POSTSUBSCRIPT italic_e start_POSTSUPERSCRIPT - italic_i italic_ω italic_t end_POSTSUPERSCRIPT, Va=Va,peiωtsubscript𝑉𝑎subscript𝑉𝑎𝑝superscript𝑒𝑖𝜔𝑡V_{a}=V_{a,p}e^{-i\omega t}italic_V start_POSTSUBSCRIPT italic_a end_POSTSUBSCRIPT = italic_V start_POSTSUBSCRIPT italic_a , italic_p end_POSTSUBSCRIPT italic_e start_POSTSUPERSCRIPT - italic_i italic_ω italic_t end_POSTSUPERSCRIPT respectively. This can be further simplified by assuming all-reactive loads ZL=iXLsubscript𝑍𝐿𝑖subscript𝑋𝐿Z_{L}=iX_{L}italic_Z start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT = italic_i italic_X start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT and couplers Z=iX𝑍𝑖𝑋Z=iXitalic_Z = italic_i italic_X, as is the case for a JPA coupled via a capacitor as long as the pump is not dissipating in the amplifier,

Pa=(|ϕp|Φ0ω)22Z0(2π)2(1+XXL)2.subscript𝑃𝑎superscriptsubscriptitalic-ϕ𝑝subscriptΦ0𝜔22subscript𝑍0superscript2𝜋2superscript1𝑋subscript𝑋𝐿2P_{a}=\frac{(|\phi_{p}|\Phi_{0}\omega)^{2}}{2Z_{0}(2\pi)^{2}}\left(1+\frac{X}{%X_{L}}\right)^{2}.italic_P start_POSTSUBSCRIPT italic_a end_POSTSUBSCRIPT = divide start_ARG ( | italic_ϕ start_POSTSUBSCRIPT italic_p end_POSTSUBSCRIPT | roman_Φ start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT italic_ω ) start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT end_ARG start_ARG 2 italic_Z start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT ( 2 italic_π ) start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT end_ARG ( 1 + divide start_ARG italic_X end_ARG start_ARG italic_X start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT end_ARG ) start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT .

We can further group the pre-factors with α=(Φ0)22Z0(2π)2𝛼superscriptsubscriptΦ022subscript𝑍0superscript2𝜋2\alpha=\frac{(\Phi_{0})^{2}}{2Z_{0}(2\pi)^{2}}italic_α = divide start_ARG ( roman_Φ start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT ) start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT end_ARG start_ARG 2 italic_Z start_POSTSUBSCRIPT 0 end_POSTSUBSCRIPT ( 2 italic_π ) start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT end_ARG and rearrange the equality to form an efficiency metric

ηPCE:=αω2|ϕp|2Pa=(XLX+XL)2.assignsubscript𝜂𝑃𝐶𝐸𝛼superscript𝜔2superscriptsubscriptitalic-ϕ𝑝2subscript𝑃𝑎superscriptsubscript𝑋𝐿𝑋subscript𝑋𝐿2\eta_{PCE}:=\frac{\alpha\omega^{2}|\phi_{p}|^{2}}{P_{a}}=\left(\frac{X_{L}}{X+%X_{L}}\right)^{2}.italic_η start_POSTSUBSCRIPT italic_P italic_C italic_E end_POSTSUBSCRIPT := divide start_ARG italic_α italic_ω start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT | italic_ϕ start_POSTSUBSCRIPT italic_p end_POSTSUBSCRIPT | start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT end_ARG start_ARG italic_P start_POSTSUBSCRIPT italic_a end_POSTSUBSCRIPT end_ARG = ( divide start_ARG italic_X start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT end_ARG start_ARG italic_X + italic_X start_POSTSUBSCRIPT italic_L end_POSTSUBSCRIPT end_ARG ) start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT .

The efficiency that the core utilizes the pump which makes it to the core node is the topic of dedicated research of its own [40], so we define this simpler metric as phase coupling efficiency (PCE). This quantity allows the circuit designer to accurately anticipate the amount of pump power that will make it to the core of the amplifier under some assumptions, and serve as useful energy to the amplification process as opposed to being reflected off of the coupler. The phase coupling efficiency, pump efficiency, and targeted output saturation power combine to determine the total power requirement of the amplifier, the relevant quantity when considering heating problems in a dilution refrigerator.

ηtotal=ηPCEηPAEsubscript𝜂𝑡𝑜𝑡𝑎𝑙subscript𝜂𝑃𝐶𝐸subscript𝜂𝑃𝐴𝐸\eta_{total}=\eta_{PCE}\cdot\eta_{PAE}italic_η start_POSTSUBSCRIPT italic_t italic_o italic_t italic_a italic_l end_POSTSUBSCRIPT = italic_η start_POSTSUBSCRIPT italic_P italic_C italic_E end_POSTSUBSCRIPT ⋅ italic_η start_POSTSUBSCRIPT italic_P italic_A italic_E end_POSTSUBSCRIPT(5)

There are some limitations to this simple calculation, the chief among them is that there must not be a zero in the denominator, or else the efficiency diverges positively at that particular frequency. At first, this appears to be a good thing. However, a positive divergence necessarily implies that the pump power to induce any phase across the load becomes arbitrarily small. This consequence is incompatible with a stiff pump, and so it appears that the PCE can only be evaluated far away from such poles.

This can be calculated for a coupling capacitor Ccsubscript𝐶𝑐C_{c}italic_C start_POSTSUBSCRIPT italic_c end_POSTSUBSCRIPT with reactance XCc=1/ωCcsubscript𝑋𝐶𝑐1𝜔subscript𝐶𝑐X_{Cc}=-1/\omega C_{c}italic_X start_POSTSUBSCRIPT italic_C italic_c end_POSTSUBSCRIPT = - 1 / italic_ω italic_C start_POSTSUBSCRIPT italic_c end_POSTSUBSCRIPT and is most useful in the approximation of driving far above resonance of the mode, where the load reactance of a parallel LC resonator is dominated by the capacitor C𝐶Citalic_C. This gives a high-frequency limit to the PCE and graphed by the dotted line in Fig.B.2 of

ηPCE=(11+Cc/C)2.subscript𝜂𝑃𝐶𝐸superscript11subscript𝐶𝑐𝐶2\eta_{PCE}=\left(\frac{1}{1+C_{c}/C}\right)^{2}.italic_η start_POSTSUBSCRIPT italic_P italic_C italic_E end_POSTSUBSCRIPT = ( divide start_ARG 1 end_ARG start_ARG 1 + italic_C start_POSTSUBSCRIPT italic_c end_POSTSUBSCRIPT / italic_C end_ARG ) start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT .
Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (9)

Power-added efficiency is not usually the dedicated focus of JPA’s fabricated in academic settings, with the primary focus usually being on quantum efficiency, bandwidth, and saturation power in that order of priority. Nonetheless, we find it interesting to review the power-added efficiencies of many JPA’s in the field. We found the first such review in [19] very helpful for perspective on the topic, and so have edited it here with some additions. While we do not make similar distinctions for total versus core power added efficiencies for all devices, due to the many differences in couplers and three versus four-wave nonlinearities employed, we still find it helpful to gauge our device’s pump efficiency in reference to other devices fabricated in the field. With this in mind, we conclude that while the core efficiency is competitive at the ηPAE=1%subscript𝜂𝑃𝐴𝐸percent1\eta_{PAE}=1\%italic_η start_POSTSUBSCRIPT italic_P italic_A italic_E end_POSTSUBSCRIPT = 1 % level, the choice of pump coupler places the ηtotalsubscript𝜂𝑡𝑜𝑡𝑎𝑙\eta_{total}italic_η start_POSTSUBSCRIPT italic_t italic_o italic_t italic_a italic_l end_POSTSUBSCRIPT of our device below the norm.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (10)

The PCE and the PAE determine the total power requirement of the amplifier, and so future work will include coupler optimization to more effectively bring down the power requirement without creating too soft of a pump. Accounting for PCE will hopefully allow future devices to operate without the use of a hot pump line and diplexer.

Appendix C Experimental details

C.1 Fabrication

Our devices were fabricated at Boulder Microfabrication Facility (BMF) at National Institute of Standards and Technology using a Nb/Al-AlOx/Nb trilayer process with low-loss amorphous silicon (a-Si) as an inter-wiring dielectric as described in [25]. From the substrate up the nominal layer thicknesses are as follows: 381-µmtimesabsentmicrometer\text{\,}\mathrm{\SIUnitSymbolMicro m}start_ARG end_ARG start_ARG times end_ARG start_ARG roman_µ roman_m end_ARG-thick intrinsic Si wafer (20kcm20timesabsenttimeskiloohmcentimeter20$\text{\,}\mathrm{k\SIUnitSymbolOhm}\text{\,}\mathrm{cm}$20 start_ARG end_ARG start_ARG times end_ARG start_ARG start_ARG roman_k roman_Ω end_ARG start_ARG times end_ARG start_ARG roman_cm end_ARG end_ARG resistivity) with 200 nm Nb, 8 nm Al-AlOx, and 110 nm Nb forming a trilayer that is patterned top-down on the substrate to define Josephson junctions and the bottom Nb wiring layer. These structures are blanketed by 310-nm-thick a-Si dielectric layer. Vias patterned through the dielectric form contacts between the junctions, or bottom wiring, and the 300-nm-thick Nb deposited as a top wiring layer over a-Si. The top and bottom wiring layers together with the low-loss a-Si between them form thin-film parallel-plate capacitors. The fabrication was further modified from the description in[31] to insert a thin bi-layer (< 20 nm) of Nb/Al between a-Si and the top Nb wiring layer to facilitate improved patterning of layers and increase device yields. The full details of the fabrication will be provided elsewhere. The top Nb wiring is bonded onto an external PCB with 1% Al-Si wirebonds to carry signals off-chip into the external environment.

C.2 Lines and external circuit elements

From its single input port, the device is driven through two different lines via a frequency diplexer with a low-pass 333\leavevmode\nobreak\ 3dB cutoff at 8.658.658.65\leavevmode\nobreak\ 8.65GHz, a high-pass 333\leavevmode\nobreak\ 3dB cutoff at 9.359.359.35\leavevmode\nobreak\ 9.35GHz, and over 808080\leavevmode\nobreak\ 80dB rejection from the high-pass port to the common port at the frequencies in this data. The high-pass line provides the pump through a very lightly attenuated (202020\leavevmode\nobreak\ 20dB attenuator at 4K4timesabsentkelvin4\leavevmode\nobreak\ $\text{\,}\mathrm{K}${}4 start_ARG end_ARG start_ARG times end_ARG start_ARG roman_K end_ARG) line, and the low-pass port receives the reflected signal from the cavity via the circulator and two Keycom 15cmtimesabsentcentimeter\text{\,}\mathrm{cm}start_ARG end_ARG start_ARG times end_ARG start_ARG roman_cm end_ARG superconducting NbTi semi-rigid coax cables. The diplexer enables rejection of the thermal noise of the high-power pump line without losing pump power at the pump frequency at the cost of additional cabling and insertion loss of approximately 111\leavevmode\nobreak\ 1dB from the diplexer, both of which must reduce the quantum efficiency of the measurement.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (11)

C.3 Flux biasing: offsets

This amplifier is sensitive to external flux offsets caused by the earth’s magnetic field as well as other stray magnetic fields such as nearby ferrite circulators and isolators. In order to shield the device from such stray fields, the amplifier package is enclosed first by a thick 6061 aluminum superconducting shell and then again by a high permeability cryoperm shield made from Amumetal 4K. Despite these precautions, we are able to see distortions in some setups, such as flux offsets even when no bias current is running through the superconducting electromagnet used to bias the amplifier, seen in Fig.C.2(b). However, freshly annealed cryoperm cans are able to reject these external flux offsets effectively, shown for a different device in Fig.C.2(a) by the high degree of symmetry around zero bias current.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (12)

C.4 Flux biasing: tunability

One factor that weighs on the choice of the quality factor in the design of the amplifier is the tunable frequency range over which the amplifier can achieve 202020\leavevmode\nobreak\ 20dB gain. Because of the low instantaneous bandwidth of a typical reflection JPA, their chief practical strength lies in their tunability to whichever frequency the readout cavity needs to be driven for measurement. Because the readout cavity frequency of a typical transmon qubit is fixed and designs vary over a few GHz for modern transmons, it is necessary to be able to tune the gain center frequency of the amplifier on the order of a few hundred megahertz or to broaden the amplifier’s gain response using an impedance matching circuit to minimize the number of separate amplifiers required to cover the entire readout band. Further, we observe that the amplifiers in the family that barely achieve 202020\leavevmode\nobreak\ 20dB gain shown on the right-hand side of Fig. 2 only achieve that gain in a narrow range of bias flux. Our devices are simulated to achieve gain for an array inductance of approximately 320320320320 to 420420420\leavevmode\nobreak\ 420pH, which gives a nominal tunable range of approximately 700700700\leavevmode\nobreak\ 700MHz measured from the maximum frequency.

In practice, however, the device achieves a much narrower tunable bandwidth than this, only about 150150150\leavevmode\nobreak\ 150MHz, which can be seen in Fig.C.5(b). One would expect that perhaps the reduction in tunable bandwidth could arise from flux nonuniformity in the array, and so we analyze this possibility next.

C.5 Flux biasing: uniformity

Our high-power JPA is biased by the use of a superconducting electromagnet set into a cutout underneath the copper amplifier package. With a mmtimesabsentmillimeter\text{\,}\mathrm{mm}start_ARG end_ARG start_ARG times end_ARG start_ARG roman_mm end_ARG-scale distance from the plane of the array to the edge of the electromagnet solenoid and the finite radius of the coil of approximately 1cm1timesabsentcentimeter1\leavevmode\nobreak\ $\text{\,}\mathrm{cm}${}1 start_ARG end_ARG start_ARG times end_ARG start_ARG roman_cm end_ARG, we anticipate that there should be very little flux nonuniformity in the array from the nonuniformity in the magnet field alone.

To investigate this, we sweep the current through the magnet over the maximum possible values without causing heating of the magnet loom connections in the refrigerator, then analyze a fast Fourier transform (FFT) of the resonant frequency modulation in Fig.C.3(b). We can then identify peaks in the spectrum in Fig.C.3(b). The transform correctly identifies the primary modulation frequency highlighted by a green vertical line about the peak value.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (13)

The origin of the second-highest peak is unknown. One possible explanation is that large superconducting planes at the boundaries of the array are shielding the first and last few rf SQUIDs from receiving the full external flux through their loops. This local shielding would be very similar on both the ground and resonator node boundaries of the array. In effort to remedy this, future efforts will include tapers to the array, diminishing the local effect of any adjacent superconductors.

C.6 Saturation power calibration

Power calibrations are often difficult to do in a straightforward way for devices at the base of a dilution refrigerator. Measurements of the input attenuation up to the plane of the amplifier at room temperature are easy, but they are often inaccurate, as all of the losses are susceptible to changes in temperature. The most straightforward way to calculate power for an amplifier serving to read out a qubit is to use the qubit as a power meter [30]. Independent measurements of the qubit can extract the χ𝜒\chiitalic_χ frequency shift of the qubit per photon in the readout cavity. This allows qubit spectroscopy at varying readout powers to directly measure steady-state power in the readout resonator by watching the qubit shift in frequency. As we show in Fig.C.4(a), after establishing this baseline with the qubit, the only tasks remaining are to link the DAC drive voltage to a voltage on a spectrum analyzer. This is simple to do by simply removing the drive from the fridge and attaching it to a spectrum analyzer, a necessary step in eliminating mixer LO leakage and tuning single-sideband upconversion in any case. The results of these calibrations as well as a similar procedures for the VNA are shown in the remaining subplots in Fig.C.4. In our case, the conversion loss of the upconversion mixer and the cable losses are roughly balanced by the additional amplification in the chain.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (14)

C.7 Saturation power variation over bias points

Many amplification schemes focus on the available bandwidth of the amplifier. Considering resonant JPA’s without matching networks typically lack instantaneous bandwidth, they typically need to be flux tuned to different operating points, and the pump moved in frequency, in order to achieve gain at a variety of frequencies. A figure of merit of such a device is the tunable bandwidth - the range where the amplifier can operate when allowing for any possible tuning. Because changing the flux bias and pump tuning of the amplifier likely affects the saturation power of the amplifier, we measure multiple bias points distributed over the rf-SQUID JPA’s tunable bandwidth of approximately 150150150\leavevmode\nobreak\ 150MHz.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (15)

We find only weak variation in the saturation power over the bias points of the amplifier, with most bias points achieving close to the average value reported in the main text. This is supported by the simulations, and similar to many previously reported results for array amplifiers [17, 19, 23].

C.8 High power measurement transitions

A natural next step in qubit measurement with a high-power JPA is to increase the power of the measurement to attain a higher integrated SNR with a shorter measurement time. While the amplifier is more than capable of handling the additional power, up to several hundred photons at this readout resonator frequency, the readout resonator plus qubit system is certainly not, as discussed in the main text. Here we show an example of how this process can go awry by showing integrated readout histograms.

In Fig.C.6(c) and (d) we give just one example of the measurement results one might expect to see when measuring at powers where the QND nature of dispersive measurement breaks down because of measurement-induced transitions in the qubit state. Transitions, which are visible as the “tracks” between states, increase in frequency at higher powers, as noted in multiple other publications [4, 5, 6, 7]. In particular, we even see transitions that are supposed to be forbidden, as well as many multi-photon transitions.

Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (16)
Simple, High Saturation Power, Quantum-limited, RF SQUID Array-based Josephson Parametric Amplifiers (2024)

References

Top Articles
Latest Posts
Article information

Author: Delena Feil

Last Updated:

Views: 5646

Rating: 4.4 / 5 (65 voted)

Reviews: 88% of readers found this page helpful

Author information

Name: Delena Feil

Birthday: 1998-08-29

Address: 747 Lubowitz Run, Sidmouth, HI 90646-5543

Phone: +99513241752844

Job: Design Supervisor

Hobby: Digital arts, Lacemaking, Air sports, Running, Scouting, Shooting, Puzzles

Introduction: My name is Delena Feil, I am a clean, splendid, calm, fancy, jolly, bright, faithful person who loves writing and wants to share my knowledge and understanding with you.